DAE file before clicking on Start LiveSync in ArchiCAD.Ĥ.3: ArchiCAD: New name in the same location The next time you click on Start LiveSync in ArchiCAD, Lumion knows that you want to use the ArchiCAD project in the same location (and with the same name) as the. Re-import the model in the Lumion Project with the.DAE file with the same name and location as the. If you have saved the ArchiCAD file under a new name (where the first 5 characters of the name are different) and/or if you have saved the ArchiCAD file in a new location, you will have to: How to re-connect: Click on Start LiveSync in ArchiCAD to re-connect. Lumion will resume the LiveSync connection if the ArchiCAD file name and location haven't changed the next time you load that Project and click on Start LiveSync in ArchiCAD. LiveSync re-connection rules for ArchiCAD 21 and newer If you have saved the Revit file in the same location but under a new name, and at least 5 consecutive characters of the new name match the old name from the last time the LiveSync connection was running, Lumion will offer you the option to re-connect via LiveSync.Ĥ. DAE file before clicking on Start LiveSync in Revit.ģ.3: Revit: New name in the same location The next time you click on Start LiveSync in Revit, Lumion knows that you want to use the Revit project in the same location (and with the same name) as the. Re-import the model in the Lumion Project with the.If you have saved the Revit file under a new name (where the first 5 characters of the name are different) and/or if you have saved the Revit file in a new location, you will have to: How to re-connect: Click on Start LiveSync in Revit to re-connect. Lumion will resume the LiveSync connection if the Revit file name and location haven't changed the next time you load that Project and click on Start LiveSync in Revit. LiveSync re-connection rules for Revit 2015 and newer How to re-connect: Re-connect via LiveSync by selecting the model and clicking on the Re-connect to LiveSync button in the Object Options panel in the top right corner.ģ. If you have saved the SketchUp file in the same location but under a new name, and at least 5 consecutive characters of the new name match the old name from the last time the LiveSync connection was running, Lumion will offer you the option to re-connect via LiveSync. SKP file before clicking on Start LiveSync in SketchUp.Ģ.3: SketchUp: New name in the same location The next time you click on Start LiveSync in SketchUp, the connection will be re-established. If you have saved the SketchUp file under a new name (where the first 5 characters of the name are different) and/or if you have saved the SketchUp file in a new location, you will have to select the SketchUp model in the Lumion Project and re-import the. How to re-connect: Click on Start LiveSync in SketchUp to re-connect. Lumion will resume the LiveSync connection if the SketchUp file name and location haven't changed the next time you load that Project and click on Start LiveSync in SketchUp. LiveSync re-connection rules for SketchUp 2017 and newer To see how to do that, please refer to the section below that applies to the 3D/CAD application that you are using:Ģ. If the model file name or location has changed significantly, you will need to re-establish the LiveSync connection manually. Lumion uses the model file name to check if models are the same or different before attempting to resume a LiveSync connection. It will do this so that a direct update to the model in Lumion can be made. LiveSync will check if the model in Revit, SketchUp, Rhino, ArchiCAD, or Vectorworks is similar to any of the models in the current Lumion Project. The following applies to LiveSync version 3 or newer.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |